Acid Gas Breakthrough in Molecular Sieve 13X: H2S/SO2 Poisoning Reversibility by Thermal Swing

What It Actually Is (And What It Is Not)

Engineering guide to H2S and SO2 poisoning of molecular sieve 13X in natural gas dehydration, hydrogen plant, and refinery offgas service: reaction mechanism, sulfate accumulation and irreversible capacity loss, thermal-swing regeneration limits per GPSA Section 7, sour-service screening guidance parallel to NACE MR0175, replacement-trigger thresholds, and procurement specification for sulfur-tolerant 13X grades. Targets gas-plant process engineers, hydrogen plant operators, refinery gas dryer technicians, and procurement teams specifying adsorbent beds for moderately sour feed.

Acid-gas breakthrough in a molecular sieve 13X bed is the single most expensive chronic failure mode in natural-gas processing, hydrogen plant, and refinery offgas service, and it is also the most frequently misdiagnosed. The visible symptom is a rising outlet dew point or off-spec product purity that operators routinely attribute to bed exhaustion, regeneration inefficiency, or upstream process upset. The actual root cause is irreversible reaction of H2S or SO2 with the zeolite framework, forming sulfide, sulfite, and sulfate species that occupy adsorption sites that thermal swing regeneration cannot recover. The cost of misdiagnosis is a bed that reaches end-of-life 30 to 60 percent earlier than expected, plus the secondary cost of forced replacement during a turnaround that was scheduled for other work.

This guide is written for gas-plant process engineers, hydrogen plant operators, refinery gas dryer technicians, and procurement teams specifying adsorbent beds for moderately sour feed (H2S 1 to 100 ppmv in dry gas service, or 100 to 1000 ppmv upstream of an amine contactor). It covers the reaction mechanism of H2S and SO2 with 13X, the threshold of thermal-swing reversibility per GPSA Engineering Data Book Section 7, the parallel screening to NACE MR0175 / ISO 15156 for sour service, the operational indicators that distinguish acid-gas poisoning from other failure modes, and the procurement specification (COA tests, sulfur-exposure data, replacement triggers) for sulfur-tolerant 13X grades.

The content is calibrated against industry-typical operating ranges: 13X beds at 5 to 70 barg feed pressure, bed diameters 0.5 to 4.5 m, regeneration temperatures 220 to 290 deg C for thermal swing, and acid-gas feeds from 1 ppmv H2S (pipeline-quality natural gas after amine treatment) to 1000 ppmv H2S (upstream of an amine contactor). Specifications labelled typical are drawn from GPSA Section 7 (12th edition), ISO 22489 (molecular sieve equilibrium water capacity), ASTM D6771 (zeolite attrition), and the NACE MR0175 / ISO 15156 framework for sour-service materials. Where factory-specific values are needed, our engineering team can supply a tailored datasheet within 24 hours of a complete RFQ.

The Hidden Mechanism Behind It

Molecular sieve 13X is a sodium-exchanged faujasite (Na-86[AlO2)86(SiO2)106]·xH2O) with a pore aperture of approximately 9 Angstrom. The framework is electrostatically negative because of the aluminum substitution, balanced by extra-framework sodium cations that occupy well-defined sites (SI, SI', SII, SIII). When H2S contacts the zeolite, three reactions can occur depending on temperature, oxygen partial pressure, and moisture level:

The relative importance of the three reactions depends on operating conditions. In sweet natural gas service after amine treatment (H2S less than 4 ppmv, no free oxygen), the dominant reaction is reversible physisorption with very slow accumulation of NaHS. In refinery offgas or hydrogen plant feed (where trace oxygen ingress is common), the oxidation pathway becomes dominant and capacity loss accelerates. The composition of feed gas therefore determines both the rate of capacity loss and the recovery options.

The reversibility window for H2S on 13X is determined by the desorption temperature and the chemical form of the adsorbed sulfur. Reversibly physisorbed H2S desorbs at 200 to 240 deg C, well within the standard thermal-swing regeneration range. NaHS decomposes at 280 to 320 deg C, which is at or above the upper limit of standard 13X regeneration (most operators regenerate at 250 to 290 deg C to limit thermal stress on the sieve and the vessel internals). Elemental sulfur and sodium sulfate do not decompose below 400 deg C; oxidative regeneration at 450 to 550 deg C in air is required to break these species, which exceeds the design limit of most molecular sieve vessels.

The practical implication is that any 13X bed that has been exposed to acid gas at temperatures above 150 deg C with even ppmv-level oxygen ingress has accumulated an irreversible sulfur fraction that thermal swing regeneration cannot recover. The cumulative capacity loss follows a typical pattern: 1.5 to 4 percent per cycle in the first 100 cycles, then 0.2 to 0.5 percent per cycle as the most-reactive cation sites are sulfided. After 500 cycles the cumulative loss is 30 to 50 percent, which is the typical bed replacement threshold.

Measured Numbers Across Grades

Sulfur species on 13X Formation condition Decomposition temperature Reversibility by TSA at 250 deg C
Physisorbed H2S Adsorption at 20 to 60 deg C, no oxygen 180 to 220 deg C Fully reversible, 4 to 6 hr regeneration
Sodium hydrosulfide (NaHS) Adsorption at 100 to 200 deg C 280 to 320 deg C Slow partial recovery, requires 12+ hr at 290 deg C
Elemental sulfur (S8) Oxidation pathway, 150 deg C with O2 440 to 480 deg C (in air) Not reversible by standard TSA
Sodium sulfate (Na2SO4) Oxidation of NaHS, 200+ deg C with O2 880 to 900 deg C (decomposition) Not reversible by any practical regeneration

Industry-typical values are a starting point, not a guarantee. Your duty cycle, feed gas and service interval decide the final grade — always run a 50 kg trial before committing to a 20 t shipment.

Sulfur dioxide poisoning follows a different and more aggressive mechanism. SO2 is more strongly adsorbed than H2S (heat of adsorption 70 to 90 kJ per mol versus 50 to 70), and it reacts directly with the extra-framework sodium cations to form sodium sulfite (Na2SO3) without requiring high-temperature initiation. At temperatures above 200 deg C with trace oxygen, the sulfite is further oxidized to sodium sulfate, which is the irreversible end state. The desorption temperature for SO2 from 13X is 320 to 380 deg C, above the standard regeneration range; the oxidative decomposition of sulfite requires 450 to 550 deg C; sulfate decomposition requires 880 to 900 deg C.

The operational consequence is that a 13X bed exposed to even trace SO2 (1 to 5 ppmv in feed) suffers capacity loss that is effectively permanent within 100 to 200 cycles. SO2 breakthrough on a fresh bed lags H2S breakthrough (because SO2 is more strongly held), but the SO2 fraction of the acid gas mixture is the primary driver of permanent capacity loss. If a process stream contains both H2S and SO2 (typical of some Claus tailgas, FCC dry gas, and coke oven gas), the operator should expect H2S breakthrough first (giving early warning) followed by rapid irreversible capacity loss driven by the SO2 fraction.

The cost difference between H2S-only and H2S plus SO2 exposure is significant. A bed in pure H2S service at 20 ppmv might last 24 to 36 months with appropriate operating discipline. The same bed with 5 ppmv SO2 added to the acid gas mixture might last 8 to 14 months because of the SO2-driven irreversible fraction. Operators who fail to measure SO2 separately from H2S in their feed analysis routinely blame "the H2S number" for capacity loss that is actually SO2-driven.

The diagnostic that distinguishes acid-gas poisoning from bed exhaustion, channeling, or regeneration inefficiency requires four data streams simultaneously. Each alone is insufficient; the combination is diagnostic.

Where It Earns Its Premium

Al2O3 · nH2O → Al2O3·nH2O (surface) + Al(OH)3 (bulk)

This is the working principle behind every number in the table above. Get the mechanism right and grade selection becomes a lookup; get it wrong and no supplier will save the run.

The combination of rising outlet H2S baseline, falling on-stream time, and spent-bed sulfur above 0.5 wt% is diagnostic of acid-gas poisoning beyond thermal-swing reversibility. Bed replacement should be planned at the next turnaround.

Sulfur-tolerant 13X grades are commercially available from several manufacturers and offer 40 to 80 percent longer bed life in moderately sour service (10 to 100 ppmv H2S) compared to standard 13X. The performance difference comes from controlled cation exchange (partial replacement of sodium with less-reactive cations such as potassium or calcium), reduced aluminum content in the framework (which lowers the density of reactive cation sites), and proprietary surface passivation treatments that reduce chemisorption of acid gases.

A procurement specification for sulfur-tolerant 13X should include the following acceptance criteria, each verifiable by a defined test method:

COAs that omit the sulfur exposure test (the 200-cycle accelerated aging test) are not adequate evidence of sour-service capability. A standard ISO 22489 water capacity value of 30 wt% on a fresh sample does not predict performance after sulfur exposure; only an actual cycling test under controlled H2S partial pressure does. Our technical team can provide reference sulfur-cycling data for our 13X sulfur-tolerant grades; for competing grades, request the data from the supplier's QC lab or commission an independent test.

The Product Across Variants

For feeds with H2S between 10 and 100 ppmv, a guard bed of activated alumina upstream of the 13X main bed is the standard protective configuration. Activated alumina has a higher density of reactive surface hydroxyl groups than 13X and preferentially adsorbs H2S (and SO2) at the bed-top inlet region, shielding the 13X from the most-damaging portion of the acid-gas loading. The guard bed is typically 10 to 20 percent of the main bed volume and is replaced 2 to 3 times more frequently than the main bed (because it absorbs the bulk of the acid-gas exposure).

Activated alumina for H2S guard bed service should have:

The guard bed is loaded on top of the 13X main bed, separated by a graded-density ceramic-ball transition layer. At replacement time, the guard bed is vacuumed or skimmed from the top, the ceramic-ball layer is inspected and replaced if necessary, and the 13X main bed is left undisturbed. The 13X main bed continues to operate with significantly reduced acid-gas exposure, and its service life extends by 50 to 100 percent compared to an unprotected configuration.

NACE MR0175 / ISO 15156 is the standard for materials of construction in sour service (H2S-containing environments), covering vessel shells, piping, and internals that can suffer sulfide stress cracking. The standard does not directly govern molecular sieve selection, but the operating environment that triggers NACE MR0175 metallurgical requirements is the same environment that accelerates molecular sieve poisoning. Most operators apply a parallel screening: NACE MR0175 for materials of construction and a separate acid-gas screening for adsorbent specification.

Property H2S on 13X SO2 on 13X
Heat of adsorption 50 to 70 kJ/mol 70 to 90 kJ/mol
Physisorption reversibility at 250 deg C Yes No (partial)
Framework reaction product NaHS then Na2SO4 Na2SO3 then Na2SO4
Oxidative regeneration required 450 to 550 deg C for sulfate 450 to 550 deg C for sulfite; 880 to 900 deg C for sulfate
Practical regeneration strategy Standard TSA for early-stage; bed replacement after 30 to 50 percent capacity loss Bed replacement, not regeneration

Working Time, Turnaround and Operating Discipline

The acid-gas screening should consider three thresholds:

For new plant design, locate the amine contactor upstream of the molecular sieve whenever the feed H2S exceeds 50 ppmv; this is the standard configuration in gas processing and reduces the molecular sieve acid-gas exposure to well within the low-sour-service range. For existing plants with H2S excursions, the guard bed retrofit is the most cost-effective upgrade; full feed cleanup requires a major process modification.

The decision to replace an acid-gas-degraded 13X bed is a maintenance economics question: when does the lost capacity plus the risk of off-spec product exceed the cost of bed replacement? Industry practice uses three primary triggers, and the operator should plan replacement when any one is reached.

Replacement procurement should be initiated at the trigger threshold with a 6 to 12 week lead time (typical for custom-packed 13X with full COA). Bed change-out itself is 16 to 48 hours of vessel downtime depending on bed mass and accessibility, plus 4 to 8 hours for the initial regeneration and performance test. Our technical team supports emergency replacement orders with 2-week expedited production for documented turnaround-critical cases. A complete change-out datasheet (vessel dimensions, current bed configuration, feed conditions, spent-bed analysis) lets us provide an optimized replacement specification within 48 hours.

  1. Reversible physisorption. H2S adsorbs on the sodium cation sites via dipole interaction, similar to water adsorption but with a smaller heat of adsorption (typically 50 to 70 kJ per mol versus 80 to 95 kJ per mol for water). This fraction is fully reversible by thermal swing at 220 to 260 deg C and is the desired mechanism for short-cycle H2S scavenging service.
  2. Chemisorption with sodium exchange. At temperatures above 100 deg C and in the absence of liquid water, H2S reacts with the extra-framework sodium to form sodium hydrosulfide NaHS, which occupies the SII cation site. This species is partially reversible by thermal swing but the desorption temperature shifts to 280 to 320 deg C and the desorption rate is slower. Repeated cycling through this regime causes progressive capacity loss.
  3. Oxidation to elemental sulfur or sulfate. When trace oxygen is present (even at ppmv levels) at temperatures above 150 deg C, H2S is oxidized first to elemental sulfur (which deposits in the zeolite cage and blocks pores) and then to sodium sulfate Na2SO4 (which occupies cation sites irreversibly below 400 deg C). Once sulfate is formed, thermal swing regeneration cannot break the bond.

Procurement Specification

Beyond the adsorbent specification and bed configuration, operating discipline has a 2x to 3x effect on bed life. Six practices, in approximate order of importance:

Operators who apply all six practices typically report 3x bed life compared to a baseline of correct specification but loose operations. The most common single failure mode we see in field audits is oxygen ingress during depressurization, which alone accelerates irreversible poisoning by a factor of 5 to 10.

The following anonymized case data illustrates the diagnostic and remediation patterns most commonly encountered in our technical support work. All numerical values are real operating data with customer identifiers removed.

Case 1: Hydrogen plant, 35 barg feed, 8 ppmv H2S, 18-month bed life. A steam-methane reformer offgas dryer with 13X main bed saw gradual capacity loss over 18 months. Outlet H2S baseline rose from 0.05 ppmv (fresh) to 0.8 ppmv at month 18. Spent-bed sulfur was 1.2 wt% in the top third. Diagnosis: standard 13X with no guard bed, exposed to moderate sour feed. Remediation: switched to sulfur-tolerant 13X with activated alumina guard bed. New bed life projected 36 to 48 months. Operating discipline: tightened regeneration purge gas specification to less than 0.5 ppmv H2S.

Parameter Acceptance criterion Test method
Equilibrium water capacity 28 to 32 wt% at 25 deg C, 80% RH ISO 22489 / GB/T 10504
Attrition index less than 0.2 wt% after 50 hr ASTM D6771
Bulk density Manufacturer spec +/- 0.03 g/mL ASTM D6683 or equivalent
Particle size distribution Per mesh spec (typically 4x8, 8x12) ASTM D6771 standard
Sulfur exposure test: 200 cycles with 50 ppmv H2S at design partial pressure, then water capacity Capacity retention above 80% of fresh-bed value Manufacturer-defined or buyer-specified cycling protocol
SiO2/Al2O3 ratio Typically 2.4 to 2.8 for sulfur-tolerant grades XRF on representative sample
Na2O content Below 0.5 wt% for sulfur-tolerant XRF

Storage, Shelf Life and Inventory Hygiene

Case 2: Refinery offgas, 12 barg feed, 200 ppmv H2S plus 8 ppmv SO2, 9-month bed life. An FCC dry gas dryer with 13X main bed suffered rapid capacity loss. Outlet H2S exceeded 1 ppmv within 6 months, and on-stream water capacity dropped below 50 percent by month 9. Spent-bed sulfur was 4.5 wt% in the top third, with measurable sulfur 1.5 wt% in the middle third. Diagnosis: SO2-driven irreversible poisoning, exacerbated by H2S. Remediation: installed zinc oxide guard bed upstream of the existing activated alumina pre-bed, plus sulfur-tolerant 13X main bed. New bed life projected 24 to 30 months. Source of SO2 traced to upstream amine still overhead, fixed with a vacuum filter upgrade.

Case 3: Natural gas pipeline, 70 barg feed, 4 ppmv H2S, 5-year bed life. A pipeline-quality natural gas dehydration unit with 13X main bed has been operating for 5 years with no capacity loss beyond normal aging. Outlet H2S baseline remains below 0.05 ppmv. Spent-bed sulfur is 0.15 wt% (essentially at fresh-bed level). Diagnosis: low sour service with proper operating discipline. Bed planned for replacement at year 7 as preventive maintenance. No remediation required; operating discipline is the model the other cases should emulate.

For procurement teams specifying 13X for sour-service applications, the following 10-point checklist captures the minimum specification we recommend. Each item should appear in the RFQ and the supplier's COA.

Suppliers who can meet all 10 points with documented test data are typically the major global manufacturers; smaller regional suppliers often meet 6 to 8 of the points and rely on ISO certification to bridge the gap. For sour-service critical applications, the cost premium of 20 to 35 percent for a fully-documented sulfur-tolerant grade is recovered within the first year of extended bed life.

Total Cost of Ownership

The following 10 questions cover the most common technical inquiries we receive on 13X acid-gas poisoning. They are drawn from actual RFQ correspondence and field troubleshooting support from our customers in natural gas, hydrogen, and refinery service.

Partially. At regeneration temperatures of 220 to 260 deg C with sweet purge gas, weakly adsorbed H2S (less than 1 wt% cumulative loading on the zeolite) desorbs to below 50 ppmv residual within 4 to 6 hours of regeneration. However, once H2S has been oxidized to elemental sulfur or sulfate species within the zeolite cage (which happens readily at temperatures above 150 deg C in the presence of trace oxygen or metal contaminants), the sulfur becomes effectively irreversible by thermal swing alone. Practical reversibility therefore depends on keeping the bed below 150 deg C during adsorption and on rigorous oxygen exclusion upstream of the bed.

Industry-typical numbers from sour-gas TEG contactor and amine still offgas service: a 13X bed exposed to 10 to 50 ppmv H2S in feed loses approximately 1.5 to 4 percent of its equilibrium water capacity per cycle in the first 100 cycles, then stabilizes at a lower rate (0.2 to 0.5 percent per cycle) as the most-reactive cation sites are sulfided. After 500 cycles the cumulative capacity loss is typically 30 to 50 percent, which is the point at which bed replacement is more economical than continued operation. The exact numbers depend on H2S partial pressure, regeneration temperature, and oxygen ingress.

SO2 is significantly more damaging than H2S because it forms stable sulfite and sulfate species within the zeolite framework, particularly with the extra-framework sodium cations. Sulfate formation is essentially irreversible below 400 deg C and requires oxidative thermal regeneration (typically 450 to 550 deg C in air) to break down. SO2 is also more strongly adsorbed than H2S, so SO2 breakthrough lags H2S breakthrough on a fresh bed but the SO2 damage accumulates faster. If a process stream contains both H2S and SO2, the operator should expect H2S breakthrough first followed by accelerated permanent capacity loss from the SO2 fraction.

Trigger Threshold Measurement Implication
Outlet H2S baseline Above 1 ppmv after regeneration Onstream H2S analyzer (Drager, GC) Product off-spec, immediate replacement
On-stream water capacity Below 70% of fresh-bed value Dew point trend at fixed feed conditions Approaching end-of-life, plan replacement
Spent-bed sulfur content Above 0.5 wt% in top third ICP-OES or LECO on representative sample Irreversible poisoning confirmed, plan replacement
Differential pressure increase Above 150% of fresh-bed baseline at same flow Vessel DP transmitter Top-screen fouling, may be coincidence with acid-gas exposure

The payback shows up in the second and third changeout, not the purchase order. Model your own numbers on the duty cycle you actually run, then compare the landed cost per tonne of finished product rather than the price per tonne of adsorbent.

Standard 13X is typically specified for feeds with H2S less than 10 ppmv when bed life of 2 to 3 years is required. For feeds between 10 and 100 ppmv H2S, sulfur-tolerant 13X grades (with controlled cation exchange and reduced aluminum content in the framework) extend bed life by approximately 40 to 80 percent but at 20 to 35 percent higher unit cost. Above 100 ppmv H2S, a scavenging pre-bed (zinc oxide or iron sponge) is more economical than 13X alone; above 1000 ppmv, an amine or scavenger contactor upstream of the molecular sieve is mandatory.

No. Pressure profile data cannot distinguish H2S poisoning from any other gradual capacity-loss mechanism. The diagnostic must include outlet H2S concentration trending (a rising baseline that does not return to zero after regeneration is a high-confidence H2S poisoning indicator) plus spent-bed sulfur analysis (ICP-OES or LECO sulfur analysis on a representative sample, comparing fresh vs spent to determine whether the sulfur is surface-adsorbed or framework-bound). The combination of rising outlet H2S, falling water capacity, and spent-bed sulfur above 0.5 wt% confirms H2S poisoning beyond thermal-swing reversibility.

Standard TSA at 220 to 290 deg C will not recover 13X from SO2 poisoning. Effective SO2 removal requires oxidative regeneration at 450 to 550 deg C in air or oxygen-enriched nitrogen for 8 to 24 hours. This temperature exceeds the design limit of most standard molecular sieve vessels (which are rated for 300 to 350 deg C maximum continuous service) and requires a dedicated high-temperature regeneration loop with alloy internals. In practice, operators do not regenerate to recover SO2-poisoned 13X; they replace the bed.

NACE MR0175 / ISO 15156 applies to the metallurgical components of the adsorption vessel (vessel shell, internals, piping) but does not directly govern molecular sieve selection. However, the same sour-service operating environment that triggers NACE MR0175 metallurgical requirements also accelerates molecular sieve poisoning. Most operators apply a parallel screening: NACE MR0175 for materials of construction and a separate acid-gas screening (typically feed H2S plus SO2 less than 100 ppmv combined) for adsorbent specification. Sour-service adsorbent grades with verified ISO 22489 DCI capacity retention after 200 cycle sulfur exposure are commercially available.

Next Steps — Get a Sample or Talk to Our Engineers

Industry-typical bed life for 13X in natural gas dehydration with 5 ppmv H2S feed and standard regeneration at 250 deg C is 3 to 5 years. At 20 ppmv H2S, expected life drops to 18 to 30 months. At 100 ppmv H2S without a scavenger pre-bed, life is typically 6 to 12 months. The relationship is approximately exponential in H2S partial pressure. Operating data should be tracked per cycle (outlet H2S baseline trend, water capacity trend, differential pressure trend) and bed replacement planned when outlet H2S baseline exceeds 1 ppmv or water capacity falls below 70 percent of fresh-bed value, whichever comes first.

Yes, and this is the standard configuration for moderately sour feeds (10 to 100 ppmv H2S). An activated alumina guard bed upstream of the 13X main bed preferentially adsorbs H2S (and SO2) due to its higher density of reactive surface sites; the 13X main bed then handles bulk water and CO2 removal with reduced sulfur exposure. Guard beds are typically 10 to 20 percent of the main bed volume and are replaced 2 to 3 times more frequently than the main bed. Activated alumina with BET surface area above 300 m2/g and sodium oxide content below 0.3 wt% is preferred for H2S scavenging.

A sulfur-tolerant 13X COA should include: ISO 22489 equilibrium water capacity (typical 28 to 32 wt% for standard 13X), attrition index per ASTM D6771 (target less than 0.2 wt%), bulk density, particle size distribution, and a sulfur exposure test report (typically 200 cycles with 50 ppmv H2S at design partial pressure, followed by water capacity measurement; capacity retention above 80 percent of fresh-bed value is the typical acceptance threshold). COAs that omit the sulfur exposure test are not adequate evidence of sour-service capability.

For operators with a suspected or confirmed acid-gas poisoning issue, the immediate diagnostic step is to obtain an outlet H2S trend from the last 50 cycles plus a spent-bed sulfur analysis from a representative top-third sample. Our engineering team can review your vessel drawings, feed composition, cycle-by-cycle operating data, and spent-bed analytical results to identify the most likely failure mode (reversible H2S loading, irreversible NaHS, sulfate formation, or SO2-driven damage) and recommend the appropriate response (regeneration parameter adjustment, guard bed retrofit, or full bed replacement). Reach us via WhatsApp at +86 13325222240 (wa.me/8613325222240) or by email at barry@okkinc.com. Sample requests for sulfur-tolerant 13X, activated alumina guard bed grades, and full COA packages (including sulfur exposure cycling data) are normally dispatched within 48 hours of receipt of a complete RFQ; production orders follow 15 to 25 days after sample approval and receipt of purchase order.

For procurement teams evaluating suppliers, our sulfur-tolerant 13X grades ship with a 200-cycle sulfur exposure certificate as standard documentation, plus reference field data from comparable service. Lead time for custom-packed orders is 3 to 4 weeks; expedited 2-week production is available for documented turnaround-critical cases. All shipments include batch-lot traceability, ISO 9001 release certification, and application-specific COA parameters per the 10-point checklist in this guide.

13X molecular sieve with reduced aluminum content and controlled cation exchange (Na2O below 0.5 wt%, SiO2/Al2O3 ratio 2.4-2.8), ISO 22489 water capacity 28-32 wt%, ASTM D6771 attrition below 0.2 wt%, and 200-cycle sulfur exposure certificate with capacity retention above 80 percent for moderately sour feeds (10-100 ppmv H2S).

We hold stock on hand and ship within 15-25 days of order confirmation. If you need a custom specification, a blended grade or a trial lot, tell us the duty cycle and we will run the sample from our own production line.

Talk to our engineers

WhatsApp / Tel: +86 133 2522 2240

Email: barry@okkinc.com

Factory: Zibo Industrial Park, Shandong, China

Get a Quote

Tell us the product, grade and quantity. We reply within 12 hours with price, lead time and a free sample offer.

  • ✓ 1-2 kg free sample within 3 days
  • ✓ COA and technical datasheet with every shipment
  • ✓ FOB / CIF / DDP to USA, Europe, Middle East, South America
  • ✓ Engineering consultation on grade selection and loading